Page 1 - 990-7080C 03/2005

990-7080C 03/2005 APC Smart-UPS Uninterruptible Power Supply Model 5000RMB User’s Manual

Page 2

4Load the UPS into the Rack and attach the Mounting Brackets Caution: The 5000 VA models (without batteries installed) require two people to lift due

Page 3

5230 Vac Units (for Hard Wire) Caution: The electrical connection must be made by an authorized electrician according to national and local regulatio

Page 4

63. Install the Batteries Note: All UPSs ship with the batteries disconnected. In addition, 5000 VA units have the batteries shipped outside the UP

Page 5 - Table of Contents

7Initial Startup Rear View 200/208 Vac 230 Vac 230 Vac with line cord Charge the battery The UPS charges its battery whenever it is connected to

Page 6

8Operating Instructions Switch On — Switch Off With the UPS plugged in, press and release the large upper on/test button to supply power to the loa

Page 7 - Unpacking

985%67%50%33%17% The 5-LED display on the left of the front panel represents the power drawn from the UPS as a percentage of total capacity. For exa

Page 8 - Installation

10Replacing the Battery This UPS has an easy to replace hot-swappable battery. Battery replacement is a safe procedure, isolated from electrical haza

Page 9

11Storage Storage Conditions Store the UPS covered and upright in a cool, dry location, with its battery fully charged. Before storing, charge the U

Page 10

12On-Battery Run Time Note: UPS battery life differs based on usage and environment. APC recommends that the battery/batteries be changed once eve

Page 11

13Specifications 200/208 Vac 230 Vac Acceptable input voltage 0 – 325 Vac Input voltage (on-line operation) 160 – 253 Vac 174 – 286 Vac 208 vol

Page 12 - 3. Install the Batteries

Entire contents copyright ©2000 by American Power Conversion Corporation. All rights reserved. Reproduction in whole or in part without permission i

Page 13 - Initial Startup

14Troubleshooting Use the chart below to solve minor UPS installation problems. Contact APC Technical Support Staff for assistance with complex UPS

Page 14 - Operating Instructions

15Service If the UPS requires service do not return it to the dealer! Follow these steps: 1. Review the problems discussed in Troubleshooting, page

Page 15

16Appendix A: Regulatory Agency Approvals 200/208 Vac Units ®LISTED 42C2E95463 LR63938 Radio Frequency Interference This equipment has been tes

Page 16 - Replacing the Battery

17Appendix B: Transporting Your Smart-UPS Follow these guidelines if you need to ship the UPS to another location. These guidelines apply whether y

Page 17 - User Configuration Items

990-7080C 03/2005 Smart UPS Safety Guide EnglishThis Safety Guide contains important instructions that should be followed during installation and ma

Page 19 - Specifications

990-7080C 03/2005 Table of Contents Introduction ...

Page 21 - Limited Warranty

1Introduction This Uninterruptible Power Supply (UPS) is designed to prevent blackouts, brownouts, sags and surges from reaching your computer and ot

Page 22 - 230 Vac Units

2Installation Installing your UPS requires five steps: 1. Position and install the UPS in the rack. This step includes installing the rails into th

Page 23 - Caution:

3Install the Mounting Rails in the Rack 1. Determine where in the rack you will mount the UPS. The SU5000 requires a space of 5U. Some racks have